Key | Issue Type | Summary | Resolution | Note |
---|---|---|---|---|
SAFETY-306 | Improvement | Weak Code Checksum: Adapt View of Checksum |
Fixed | [[GENERAL]] For activating the new calculation of the Application ID, the following setting needs to be added to the device description of a safety PLC. The version needs to be 4.2.0.0 or higher. <ts:TargetSettings ...> <ts:section name="runtime_identification"> <ts:setting name="safe_control_core_version" type="string" access="visible"> <ts:value>4.2.0.0</ts:value> </ts:setting> </ts:section> ... </ts:TargetSettings> |
SAFETY-300 | Bug | SafetyObjects: Drag'n'Drop of a SafePOU on a SafeTask deletes the SafePOU |
Fixed | |
SAFETY-298 | Improvement | Read Safety Application ID: Enable command in context menu |
Fixed | |
SAFETY-295 | Bug | Online Change vPLC: connection loss, not possible to send application |
Fixed | |
SAFETY-293 | Improvement | SafeNetVar: Increase number of receivers per sender |
Fixed | [[GENERAL]] For changing the maximum number of safety netvar receivers, the following OEM Customization Hook can be used: Section: "SafetyEditor" Key: "SafetyCustomNetVarsMaxReceivers" Type: INT Range: 1 -> 1024 If this hook is used, it is the responsibility of the device manufacturer to test the functionality of the system itself. |
SAFETY-290 | Bug | SafetyEditor: Remove OEMCustomization for disabling precompile cache. |
Fixed | |
SAFETY-274 | Bug | Exception in editor when doubleclicking a variable and moving mouse while holding second click |
Fixed | |
SAFETY-268 | Improvement | Safety Extension: Adjustments to the function "Read Safety Application ID" |
Duplicate | |
SAFETY-266 | Bug | Multiple dialogs with "Mapping channel type "float" is not supported", no further input in CODESYS possible |
Fixed | |
SAFETY-239 | Bug | Input Assistent: Assistent does not show FB instances of logical devices |
Cannot Reproduce |