Release Notes: CODESYS Automation Server 1.39.0.0

Key Issue Type Summary Resolution Note
CAS-5084 Improvement

[WebApp] Download project archive additional to "open with CODESYS"

Fixed [[GENERAL]]
Projects can be downloaded as project archives.
CAS-5064 Bug

[Server] [WebApp] Application not properly removed

Fixed [[GENERAL]]
A bug has been fixed whereby, in projects containing multiple PLC-compatible applications, it was possible to trigger the undeploy of an application that had not been deployed. The user interface reported success, but correctly, no action was performed.
CAS-5035 Improvement

Show Gateway ID in WebApp

Fixed [[GENERAL]]
It is now possible to retrieve the ID of a gateway in the gateway table. This simplifies the process of manually adding a remote gateway in the CODESYS IDE via the 'Add New Gateway' option in the Device Editor.
CAS-4967 Bug

[Server] EdgeApi message acknowledge missing

Fixed [[GENERAL]]
This fixes problems with disconnected or failing Edge Gateways when the connection between the Automation Server and the Edge Gateway remains open for an extended period of time and the connected PLCs have deplyoed applications with frequent parameter changes.
CAS-4953 Improvement

[WebApp] Add logger page for Edge Gateways

Fixed [[GENERAL]]
It is now possible to display the logs of the Edge Gateways in the Server Web UI. In the dialog opened via “View logs” for an Edge Gateway in the Gateway list, a new tab has been added that allows you to retrieve the logs.
This can be used in combination with CAS-4952 to investigate connection issues between the Edge Gateway and the PLCs.
CAS-4952 Improvement

[WebApp] Add PLCHandler logger configuration

Fixed [[GENERAL]]
PLCHandler log filters are configurable for PLCs.
CAS-4951 Improvement

[Server] Add PLCHandler Log Filter configuration

Fixed
CAS-4908 Improvement

Remove the byte display in file management

Fixed
CAS-4886 Epic

File Management II b

Fixed [[GENERAL]]
Since the last Automation Server release, you have already been able to store files centrally on your Automation Server.
Now you can deploy these additional files to PLCs alongside the actual CODESYS application.
Your deployments no longer only contain the application but can now cover a much broader scope, such as configuration files, recipes, production information etc.
CAS-4836 Improvement

[Server] Fetch Device Log for Edge Gateways

Fixed [[GENERAL]]
Edge Gateway logs can be retrieved using the Automation Server.
CAS-4362 Improvement

[Server] Copy Refreshed Encrypted Communication Certificate when Using Encryption with CAS

Fixed [[GENERAL]]
When renewing a PLC certificate for encrypted communication, the new certificate can now be automatically installed on the corresponding Edge Gateway.
CAS-4050 Improvement

[Server] Download Project Archive instead of "Open with CODESYS"

Fixed [[GENERAL]]
Projects can be downloaded from the Automation Server as project archives.