Release Notes: CODESYS V3.5 SP21 Patch 6

Key Issue Type Summary Resolution Note
CDS-97859 Bug

CLONE - DeviceObject: Update device removes manual change

Fixed
CDS-97856 Bug

CLONE - Compiler: Property with only Set accessor of type REFERENCE TO struct leads to compile error

Fixed
CDS-97703 Bug

CLONE - User Management, Import: Import leads to endless Credential prompt with disabled Device User Management

Fixed
CDS-97700 Bug

CLONE - CmpOPCUAServer, CmpOPCUAStack: Harden AuditLogs against specifiers placed in user defined text

Fixed [[GENERAL]]
For more details see CODESYS Security Advisory 2026-03, which is available on the CODESYS website:
https://api-www.codesys.com/fileadmin/user_upload/CODESYS_Group/Ecosystem/Up-to-Date/Security/Security-Advisories/Advisory2026-03_CDS-95911.pdf
CDS-97699 Bug

CLONE - CmpAuditLog: Format specifiers can lead to DOS

Fixed [[GENERAL]]
For more details see CODESYS Security Advisory 2026-03, which is available on the CODESYS website:
https://api-www.codesys.com/fileadmin/user_upload/CODESYS_Group/Ecosystem/Up-to-Date/Security/Security-Advisories/Advisory2026-03_CDS-95911.pdf
CDS-97584 Bug

CLONE - Internal error and compile error when calling functions with ANY inputs

Fixed [[GENERAL]]
CompilerVersion >= 3.5.21.60
CDS-97532 Bug

CLONE - Compile: Access Violation with __Currenttask-Operator

Fixed
CDS-97528 Bug

CLONE - CmpSchedule: Unexpected Watchdog Timeout exceptions

Fixed
CDS-97523 Bug

CLONE - LacUtil: Exception during LAC installation prevents references from being installed

Fixed [[GENERAL]]
The LacUtil executable now features improved error handling for reference installations. If an error occurs in this context, the return value 3 will be returned.
Since the original issue was caused by a referenced GAC installation that resulted in a target path exceeding 260 characters, LacUtil is now capable of handling long paths correctly.

[[KNOWN_LIMITATIONS]]
LACUtil.exe will not start if the path <RootFolder>\LacBinaries\GAC_MSIL\Utilities\3.5.23.0__83380e73b2486719\Utilities.dll is longer than 260 characters. .Net internal loading from redirected paths does not work with long paths as well.

[[COMPATIBILITY_INFORMATION]]
LACUtil.exe now has new dependencies on Utilities.dll and PInvoke.dll, according to the assembly redirects placed in the LacBinaries folder.
LACUtil.exe works well within the Common directory. If it is used outside a CODESYS installation, both referenced DLLs must be copied along as well. Additionally, the LACUtil.exe.config file must be deleted.
CDS-97520 Bug

CLONE - Project Compare: Commit Device Changes makes Device unusable

Won't Fix [[GENERAL]]
Too risky for a patch as changes in device object is required. Without a full regression test it is to dangerous -> won't fix
CDS-97470 Bug

CLONE - Library Manager: Documentation shows BLACK background and text when Windows color set to Dark

Fixed
CDS-97462 Bug

CLONE - Incorrect message in the use case that a device does not support any boot project at all

Fixed [[GENERAL]]
The additional warning introduced for CDS-85812 will no longer be shown for devices that do not support a boot application.
It will also not be shown when the simulation mode is active for a device.
CDS-97460 Bug

CLONE - Message View: Project with EnternetIP leads to exception

Fixed
CDS-97458 Bug

CLONE - SymbolConfig: OnlineChange fails due to changes in the SymbolConfig

Won't Fix [[GENERAL]]
Won't fix. The original issue CDS-95679 does not contain any relevant source changes, there is nothing to patch here.

The project reports three instance of "Internal Error 2" during OnlineChange:
One instance was fixed with CDS-95522 in CODESYS 3.5 SP22 and has been patched into CODESYS 3.5 SP21 Patch 5 with with CDS-97034.

The two remaining issues have been fixed with CDS-95448 in CODESYS 3.5 SP22 which relies on a major rework of the compile process in SP22 and cannot be backported to SP21.

Workaround:
The release note of CDS-95448 describes a workaround: Avoid using ANY-type conversion operators for initial value declarations.
For this specific case: The library diagutil, 1.3.10.5 contains several functions where VAR_INPUT cSeparator is initialized using an ANY_TO_BYTE expression:
cSeparator : BYTE := ANY_TO_BYTE(';');
Change this to
cSeparator : BYTE := 59; // semicolon

Please note that STRING_TO_BYTE does not convert characters to ASCII bytes. Instead it tries to parse a number from a string (similar to STRING_TO_INT).
CDS-97271 Bug

CLONE - CmpOPCUAServer: Crash if CloseSession (or another service) is called before ActivateSession has finished

Fixed
CDS-97215 Improvement

CLONE - DeviceRepository: internal speed improvements

Fixed
CDS-97208 Bug

CLONE - VxWorks 7 : Imbalance of handling reference counts for END devices

Fixed
CDS-97202 Bug

CLONE - CmpHilscherCIFX : Check customer feedback and fixes for message handling problems

Won't Fix [[GENERAL]]
Requested patch cannot be integrated:
- Caused errors in CODESYS fieldbus regressions tests
- Customer errors cannot be reproduced in our environment
CDS-97098 Improvement

CLONE - AddOn Check for PLCNext module should be removed

Fixed
CDS-96812 Improvement

CLONE - [Project Inspection] Possibility to modify add-ons for creating a new installation

Fixed [[GENERAL]]
Two new OEMCustomization Hooks
1. Filter to modify required add-ons
Section: InstallerIntegration;
Key: FilterRequiredAddOns;
Data Type: Func<IEnumerable<IAddOnInformation>, IEnumerable<IAddOnInformation>>

2. Filter to modify optional add-ons
Section: InstallerIntegration;
Key: FilterOptionalAddOns;
Data Type: Func<IEnumerable<IAddOnInformation>, IEnumerable<IAddOnInformation>>

The first parameter of the Func<> is the original list determined by project inspection, where the return value is the modified (or cleared) list.
CDS-96158 Bug

CLONE - DeviceEditor: additional empty IO-Mapping page is shown

Fixed

 

CODESYS AddOns Version
CODESYS Automation Server Connector 1.38.0.0
CODESYS Base Libraries 4.0.1.0
CODESYS SoftMotion 4.20.2.0
CODESYS Security Agent 1.4.0.0
CODESYS C Code Integration 4.0.0.0
CODESYS Core Dump 4.2.0.0
CODESYS Code Generator ARM 4.0.3.0
CODESYS Code Generator ARM64 4.0.1.0
CODESYS Code Generator Blackfin 4.0.0.0
CODESYS Code Generator Cortex M3 4.0.2.0
CODESYS Code Generator PowerPC 4.0.2.0
CODESYS Code Generator RX 4.0.0.0
CODESYS Code Generator SH 4.0.0.0
CODESYS Code Generator TIC28x 4.0.0.0
CODESYS Code Generator TriCore 4.0.1.0
CODESYS Compiler Versions Archive 4.0.0.0
CODESYS Communication 4.7.0.0
CODESYS RISC Front End 4.0.2.0
CODESYS Target Settings Export 4.0.0.0
CODESYS Trace 4.3.0.0
CODESYS IO-Link 4.3.0.0
CODESYS Safety Support 4.1.0.0
CODESYS Redundancy 4.2.0.0
CODESYS NetX 4.0.0.0
CODESYS Memory Tools 4.1.0.0
CODESYS Modbus 4.5.0.0
CODESYS Ethernet Adapter 4.2.0.0
CODESYS EtherCAT 4.10.0.0
CODESYS CANopen 4.3.0.0
CODESYS EDS Import 4.3.0.0
CODESYS EtherNetIP 4.8.0.0
CODESYS PROFIBUS 4.2.0.0
CODESYS SAE J1939 4.2.0.0
CODESYS PROFINET 4.7.2.0
CODESYS Scripting 4.2.0.0
CODESYS Recipes 4.7.0.0
CODESYS Embedded Runtime Extension 4.1.0.0
CODESYS Device Reader 4.0.0.0
CODESYS Visualization Support 4.7.0.0
CODESYS Visualization 4.9.1.0
CODESYS CFC 4.5.0.0
CODESYS Application Composer 4.4.0.0
CODESYS LD FBD 4.6.0.0
CODESYS SFC 4.4.0.0
CODESYS Ladder 1.2.0.0
CODESYS Usage Analysis 1.2.0.0
CODESYS String Libraries 4.1.0.0
CODESYS Library Dependency Inspection 1.1.0.0
CODESYS Math Libraries 4.0.0.0